| Product ::- Fire Extinguishers & Fire Fighting Equipments |
| |
|
|
| |
ABC TYPE FIRE EXTINGUISHER |
|
| |
Store Pressure ( Multipurpose Fire Extinguisher ) |
|
| |
"THIS BRAND" BIS APPROVED ISI MARK ABC TYPE FIRE EXTINGUISHER COVERS A,B,C CLASS OF FIRES WHICH INCLUDE PAPERS, WOOD, CLOTH RUBBER, PLASTIC & INFLAMMABLE LIQUID LIKE OIL, PETROL, PAINTS, PETROCHEMICAL PRODUCT, RESINS, GASES IN THE COMPRESSED FROM ACETYLENES, LPG & CNG, ELECTRICAL & SOPHISTICATED ELECTRICAL EQUIPMENT. |
|
| |
|
|
| |
Technical Specification : |
|
| |
|
|
| |
Capacity (in Kg)
|
500 gm
|
1
|
2
|
5
|
10 |
IS Specification
|
13849
|
13849
|
13849
|
13849
|
13849 |
Jet Range (In Mtr.)
|
1.5
|
2-4
|
2-4
|
4-5
|
<6 |
Discharge Time (In Sec.)
|
6-8
|
8-10
|
8-10
|
15-20
|
23-30 |
Min. Discharge Quantity
|
85%
|
85%
|
85%
|
85%
|
85% |
Seal of Approval
|
ISI
|
ISI
|
ISI
|
ISI
|
ISI |
Hydraulic Test Pressure of Cylinder (Kg./Cm2)
|
30
|
30
|
30
|
30
|
30 |
| Discharge Outlet |
Direct Nozzle |
Direct Nozzle
|
Direct Nozzle |
Direct Nozzle |
Direct Nozzle |
|
|
| |
WATER CO2 TYPE FIRE EXTINGUISHER FOR "A" CLASS OF FIRE |
|
| |
"THIS BRAND" BIS APPROVED ISI MARK ABC TYPE FIRE EXTINGUISHER & WATER STORE PRESSURE TYPE PROVIDES SAFETY AGAINST "A" CLASS OF THE FIRE WHICH INVOLVES MATERIAL LIKE WOOD, PAPER, CLOTH, PLASTICS & FIBER, RUBBER ETC. |
|
| |
CAUTION : NOT TO BE USED ON ELECTRICAL FIRES |
|
| |
|
|
| |
Technical Specification
|
Water CO2 Store Pressure
|
Water CO2
|
Water CO2
|
Capacity (In Ltr.)
|
9
|
9
|
50
|
IS Specification
|
6234
|
940
|
13385
|
Jet Range (In Mtr.)
|
<6
|
<6
|
10
|
Discharge Time (In Sec.)
|
60-90
|
60-120
|
60-180
|
Min. Discharge Quantity
|
95%
|
95%
|
90%
|
Seal of Approval
|
ISI
|
ISI
|
-
|
Hydraulic Test Pressure of
Cylinder (Kg./Cm2) |
30 |
30
|
30 |
|
|
| |
DRY CHEMICAL POWDER TYPE FIRE EXTINGUISHER FOR "B" & "C" CLASS OF FIRE |
|
| |
"THIS BRAND" BIS APPROVED ISI MARK DRY CHEMICAL FIRE EXTINGUISHER CONTROL B & C CLASS OF FIRE LIKE OIL, PETROL AND PETROLEUM PRODUCT, SOLVENT, PAINTS, VARNISHES, CHEMICAL LIQUIDS, ALL FLAMMABLE LIQUIDS & ELECTRICAL FIRE & GAS FIRE, ETC. |
|
| |
|
|
| |
| Technical Specification |
| Capacity (In Ltr.) |
5 |
10 |
25 |
50 |
75 |
| IS Specification |
2171 |
2171 |
10658 |
10658 |
10658 |
| Jet Range (In Mtr.) |
4-5 |
<6 |
<6 |
8-10 |
10-12 |
| Discharge Time (In Sec.) |
15-20 |
25-30 |
25-30 |
40-50 |
50-60 |
| Min. Discharge Quantity |
90% |
90% |
85% |
85% |
85% |
| Seal of Approval |
ISI |
ISI |
- |
- |
- |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
30 |
30 |
30 |
30 |
30 |
|
|
| |
CARBON DIOXIDE TYPE FIRE EXTINGUISHER FOR "B" & "C" CLASS OF FIRE |
|
| |
"THIS BRAND" CARBON DIOXIDE TYPE FIRE EXTINGUISHER ARE SUITABLE FOR B & C CLASS OF FIRES INVOLVING ALL FLAMMABLE LIQUIDS, GASES, LIVE & DELICATE, MACHINERY FIRES, ELECTRICAL & SOPHISTICATED ELECTRONIC EQUIPMENTS FIRES TRASNFORMER & SWITCH GEAR FIRE. THIS EXTINGUISHER IS APPROVED BY EXPLOSIVE DEPARTMENT, GOVT. OF INDIA, NAGPUR |
|
| |
THE NEW CO2 SQUEEZE GRIP TYPE PORTABLE FIRE EXTINGUISHER ALSO AVAILABLE |
|
| |
|
|
| |
| Technical Specification |
| Capacity (In Kg.) |
2 |
3 |
4.5 |
6.5 |
9 |
22.5 |
| IS Specification |
2878 |
2878 |
2878 |
2878 |
2878 |
2878 |
| Jet Range (In Mtr.) |
2 |
2 |
2.5-3 |
2.5-3 |
2.5-3 |
2.5-3 |
| Discharge Time (In Sec.) |
14-16 |
16-18 |
20-24 |
25-30 |
30-35 |
50-60 |
| Min. Discharge Quantity |
98% |
98% |
98% |
98% |
98% |
98% |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
250 |
250 |
250 |
250 |
250 |
250 |
| Working Pressure (Kg./Cm2) |
60-65 |
60-65 |
60-65 |
60-65 |
60-65 |
60-65 |
|
|
| |
MECHANICAL FOAM (AFFF) FIRE EXTINGUISHER FOR "A" & "B" CLASS OF FIRE |
|
| |
"THIS BRAND" MECANICAL FOAM TYPE FIRE EXTINGUISHER IS DESIGNED TO EXTINGUISH A & B CLASS OF FIRE INVOLVING WOOD, PAPER, CLOTH, TEXTILE, STATIONERY & VERY SPECIAL BLANKET EFFECT ON FLAMMABLE & VOLATILE LIQUIDS LIKE OIL, PETROL, KEROSENE, SOLVENT & CHEMICAL, WAX, RESINS ETC. |
|
| |
CAUTION : NOT TO BE USED ON ELECTRICAL FIRES |
|
| |
|
|
| |
Technical Specification |
MECH.FOAM |
MECH.FOAM |
MECH FOAM STORE
PRESSURE |
| Capacity (In Kg.) |
9 |
50 |
9 |
| IS Specification |
10204 |
13386 |
15397 |
| Jet Range (In Mtr.) |
<6 |
10 |
<6 |
| Discharge Time (In Sec.) |
60-90 |
60-180 |
25-60 |
| Min. Discharge Quantity |
95% |
90% |
90% |
| Hydraulic Test Pressure of Cylinder (Kg./Cm2) |
30 |
30 |
30 |
|
|
| |
AUTOMATIC MODULAR FIRE EXTINGUISHER A B C E CLASS OF FIRE |
|
| |
Contents: Automatic ABC Dry Power, Dry Chemical Powder, FM-200 etc. |
|
| |
Operation: When heat from an uncontrolled fire increases to a pre-set temperature of the unit, the fusible link releases discharging the extinguishing agent. The releases temperature of the extinguisher (fusible link) can be preset at works ranging from 570c/680c/790c/930c/1400c and so on. They require no external source of energy and it can be operated electrically, manually or mechanically for their-operation.(Optionally) |
|
|
| |
Applicability for General Occupancies & Storage Areas like : Storage of Flammable & Combustible Liquids & Gases, Chemicals, Grain Mill Products, Solids Fuels, Records, Libraries, Museums, Showrooms, Shops, Offices, Residential premises, Workshop, Garages, Paint Booths, Theatre, Radio Rooms TV Stations etc. |
|
| |
|
|